Free sample US customary units
A circular primary clarifier at a wastewater treatment plant has an inside diameter of 60 ft and treats a flow of 2.4 MGD. The surface overflow rate of the clarifier (gpd/ft²) is most nearly:
- A212
- B667
- C849
- D12,700
Work it out first. On the exam you would have about three minutes.
Show the answer and worked solutionHide the answer and worked solution
AnswerC849
Find it in the Handbook
Environmental Engineering
Clarifier
Clarifier overflow rate, (plan area)
Search (Ctrl+F)
Given
- Circular clarifier, diameter ft
- Flow MGD
Find
Surface overflow rate, (gpd/ft²)
Surface area
The overflow rate uses the plan (top-view) area of the tank: ft².
Overflow rate
The overflow rate is the flow divided by the surface area. A flow of 2.4 MGD is 2,400,000 gal/day, so gpd/ft².
Why the other choices are wrong
- A212 gpd/ft² comes from using the diameter as the radius: ft², four times too large, and . With the diameter, the area is ft².
- B667 gpd/ft² comes from using ft², the area of a square tank 60 ft on a side: . A circle covers only of that square: ft².
- D12,700 comes from dividing the flow by the circumference of the tank, ft: gpd/ft. That is a weir loading, a flow per foot of weir. The overflow rate divides by the surface area, 2827 ft².
Exam-day tip
Overflow rate uses the surface area (gpd/ft²); weir loading uses the weir length (gpd/ft). The units in the question tell you which one is wanted.