Skip to content

Free in December. Through December 31, every feature for every exam is free with a free account. No plan, no card.

Free through December 31. Every feature for every exam, free with an account. No plan, no card. Create a free account

Free through December 31. Your account has every feature for every exam until then.

Water and wastewater treatment

Water and wastewater treatment is one of the subtopics of Water Resources and Environmental Engineering in the FE Civil exam specification. Questions here are short: one scenario, four choices and about three minutes to answer with the FE Reference Handbook open beside you.

What you can be asked

These are the ideas our problems on Water and wastewater treatment are built around. Each one is covered by at least one problem in the bank.

  • Detention time
  • Overflow rate of a clarifier
  • Settling velocity (Stokes)
  • Chlorine dose and demand / CT
  • Activated sludge F/M or SRT
  • Filtration rate
  • Chemical dosage feed rate
  • Sludge volume / solids mass

Our practice bank has 13 problems on water and wastewater treatment. Every problem is a calculation with a numeric answer. 7 use SI units and 6 use US customary units, as the exam mixes both.

Try one: a free Water and wastewater treatment problem

The solution shows the steps with units, where the equation sits in the Handbook, and the mistake behind each wrong choice.

Free sample US customary units

A circular primary clarifier at a wastewater treatment plant has an inside diameter of 60 ft and treats a flow of 2.4 MGD. The surface overflow rate of the clarifier (gpd/ft²) is most nearly:

  1. A212
  2. B667
  3. C849
  4. D12,700

Work it out first. On the exam you would have about three minutes.

Show the answer and worked solution

AnswerC849

Find it in the Handbook

Environmental Engineering

Clarifier

Clarifier overflow rate, (plan area)

Search (Ctrl+F)

Overflow rateHydraulic loading rate

Given

  • Circular clarifier, diameter ft
  • Flow MGD

Find

Surface overflow rate, (gpd/ft²)

  1. Surface area

    The overflow rate uses the plan (top-view) area of the tank: ft².

  2. Overflow rate

    The overflow rate is the flow divided by the surface area. A flow of 2.4 MGD is 2,400,000 gal/day, so gpd/ft².

Why the other choices are wrong

  • A212 gpd/ft² comes from using the diameter as the radius: ft², four times too large, and . With the diameter, the area is ft².
  • B667 gpd/ft² comes from using ft², the area of a square tank 60 ft on a side: . A circle covers only of that square: ft².
  • D12,700 comes from dividing the flow by the circumference of the tank, ft: gpd/ft. That is a weir loading, a flow per foot of weir. The overflow rate divides by the surface area, 2827 ft².

Exam-day tip

Overflow rate uses the surface area (gpd/ft²); weir loading uses the weir length (gpd/ft). The units in the question tell you which one is wanted.

Practice more Water and wastewater treatment

The bank has 13 problems on this subtopic and 100 across Water Resources and Environmental Engineering. Practice quizzes are part of membership. Not a member yet? The free diagnostic shows which areas to work on first. Through December 31, practice quizzes are free with a free account.