Skip to content

Free in December. Through December 31, every feature for every exam is free with a free account. No plan, no card.

Free through December 31. Every feature for every exam, free with an account. No plan, no card. Create a free account

Free through December 31. Your account has every feature for every exam until then.

Collection systems

Collection systems is one of the subtopics of Water Resources and Environmental Engineering in the FE Civil exam specification. Questions here are short: one scenario, four choices and about three minutes to answer with the FE Reference Handbook open beside you.

What you can be asked

These are the ideas our problems on Collection systems are built around. Each one is covered by at least one problem in the bank.

  • Sanitary sewer design flow and peaking
  • Sewer velocity and slope
  • Partially full pipe flow
  • Infiltration and inflow

Our practice bank has 8 problems on collection systems. Every problem is a calculation with a numeric answer. 4 of them come with a diagram. 4 use SI units and 4 use US customary units, as the exam mixes both.

Try one: a free Collection systems problem

The solution shows the steps with units, where the equation sits in the Handbook, and the mistake behind each wrong choice.

Free sample US customary units

A trunk sanitary sewer serves a population of 25,000 with an average wastewater flow of 100 gal per person per day. The ratio of peak to average sanitary flow is (18 + √P)/(4 + √P), where P is the population in thousands. An infiltration allowance of 0.30 MGD is added to the peak sanitary flow without being peaked. The design flow for the sewer (MGD) is most nearly:

  1. A2.80
  2. B3.02
  3. C6.39
  4. D6.69

Work it out first. On the exam you would have about three minutes.

Show the answer and worked solution

AnswerD6.69

Find it in the Handbook

Civil Engineering

Sewage Flow Ratio Curves

Sewage Flow Ratio Curves, Curve G: peak-to-average ratio , with the population in thousands

Search (Ctrl+F)

Sewage Flow Ratio CurvesPopulation in Thousands

Given

  • Population 25,000, so (thousands)
  • Average flow 100 gal per person per day
  • Peak-to-average ratio
  • Infiltration allowance 0.30 MGD (not peaked)

Find

Design (peak) flow, (MGD)

  1. Average sanitary flow

    gal/day MGD.

  2. Peaking factor

    The curve uses the population in thousands, so and . The ratio is .

  3. Peak sanitary flow plus infiltration

    Only the sanitary flow is peaked: MGD. Infiltration is a steady allowance added on top: MGD.

Why the other choices are wrong

  • A2.80 MGD comes from adding the infiltration to the average flow, MGD, and never applying the peak-to-average ratio. The sewer must carry the peak: multiply the 2.50 MGD by 2.556 first.
  • B3.02 MGD comes from entering the population in persons: , so the ratio is and the flow is MGD. is in thousands: use , which gives a ratio of 2.556.
  • C6.39 MGD is the peak sanitary flow alone, MGD. The design flow also includes the infiltration allowance: add 0.30 MGD to reach 6.69 MGD.

Exam-day tip

Peaking-factor curves are written for population in thousands. If your factor comes out barely above 1 for a small town, you probably entered the population in persons.

Practice more Collection systems

The bank has 8 problems on this subtopic and 100 across Water Resources and Environmental Engineering. Practice quizzes are part of membership. Not a member yet? The free diagnostic shows which areas to work on first. Through December 31, practice quizzes are free with a free account.

More in Water Resources and Environmental Engineering