Free sample US customary units
A trunk sanitary sewer serves a population of 25,000 with an average wastewater flow of 100 gal per person per day. The ratio of peak to average sanitary flow is (18 + √P)/(4 + √P), where P is the population in thousands. An infiltration allowance of 0.30 MGD is added to the peak sanitary flow without being peaked. The design flow for the sewer (MGD) is most nearly:
- A2.80
- B3.02
- C6.39
- D6.69
Work it out first. On the exam you would have about three minutes.
Show the answer and worked solutionHide the answer and worked solution
AnswerD6.69
Find it in the Handbook
Civil Engineering
Sewage Flow Ratio Curves
Sewage Flow Ratio Curves, Curve G: peak-to-average ratio , with the population in thousands
Search (Ctrl+F)
Given
- Population 25,000, so (thousands)
- Average flow 100 gal per person per day
- Peak-to-average ratio
- Infiltration allowance 0.30 MGD (not peaked)
Find
Design (peak) flow, (MGD)
Average sanitary flow
gal/day MGD.
Peaking factor
The curve uses the population in thousands, so and . The ratio is .
Peak sanitary flow plus infiltration
Only the sanitary flow is peaked: MGD. Infiltration is a steady allowance added on top: MGD.
Why the other choices are wrong
- A2.80 MGD comes from adding the infiltration to the average flow, MGD, and never applying the peak-to-average ratio. The sewer must carry the peak: multiply the 2.50 MGD by 2.556 first.
- B3.02 MGD comes from entering the population in persons: , so the ratio is and the flow is MGD. is in thousands: use , which gives a ratio of 2.556.
- C6.39 MGD is the peak sanitary flow alone, MGD. The design flow also includes the infiltration allowance: add 0.30 MGD to reach 6.69 MGD.
Exam-day tip
Peaking-factor curves are written for population in thousands. If your factor comes out barely above 1 for a small town, you probably entered the population in persons.