Skip to content

Free in December. Through December 31, every feature for every exam is free with a free account. No plan, no card.

Free through December 31. Every feature for every exam, free with an account. No plan, no card. Create a free account

Free through December 31. Your account has every feature for every exam until then.

Groundwater

Groundwater is one of the subtopics of Water Resources and Environmental Engineering in the FE Civil exam specification. Questions here are short: one scenario, four choices and about three minutes to answer with the FE Reference Handbook open beside you.

What you can be asked

These are the ideas our problems on Groundwater are built around. Each one is covered by at least one problem in the bank.

  • Darcy's law
  • Seepage velocity and porosity
  • Unconfined well (Dupuit)
  • Confined well (Thiem)
  • Transmissivity and storativity

Our practice bank has 10 problems on groundwater. Every problem is a calculation with a numeric answer. 9 of them come with a diagram. 6 use SI units and 4 use US customary units, as the exam mixes both.

Try one: a free Groundwater problem

The solution shows the steps with units, where the equation sits in the Handbook, and the mistake behind each wrong choice.

Free sample SI units

A well fully penetrates an unconfined aquifer that has a hydraulic conductivity of 25 m/day and rests on a horizontal impermeable base. Before pumping, the water table is 20 m above the base. After the well has been pumped at a constant rate long enough to reach steady state, the drawdown is 3.5 m in an observation well 15 m from the pumped well and 2.0 m in an observation well 60 m from the pumped well. The pumping rate (m³/day) is most nearly:

  1. A467
  2. B2,930
  3. C3,400
  4. D6,750

Work it out first. On the exam you would have about three minutes.

Show the answer and worked solution

AnswerB2,930

Find it in the Handbook

Civil Engineering

Dupuit's Formula

Dupuit's Formula,

Search (Ctrl+F)

Dupuit's FormulaUnconfined aquifer

Given

  • Unconfined aquifer, m/day, initial saturated thickness m
  • Drawdown m at m
  • Drawdown m at m
  • Steady state, fully penetrating well

Find

Steady pumping rate,

  1. Convert drawdowns to water heights above the base

    The unconfined well equation uses the height of the water table above the bottom of the aquifer, not the drawdown. m at 15 m and m at 60 m.

  2. Form the two terms of the equation

    In an unconfined aquifer the flow area shrinks as the water table drops, which is why the heights are squared: m². The radii enter through a natural log: .

  3. Solve for the pumping rate

    m³/day.

Why the other choices are wrong

  • A467 m³/day comes from putting the drawdowns into the formula as if they were heights: m³/day. Dupuit's is measured up from the aquifer bottom, so subtract each drawdown from 20 m first: 16.5 m and 18.0 m.
  • C3,400 m³/day comes from the confined-aquifer form with a constant thickness of 20 m: m³/day. In an unconfined aquifer the saturated thickness shrinks toward the well, which is why Dupuit's formula uses m² instead.
  • D6,750 m³/day comes from using the base-10 logarithm: , and m³/day. The formula uses the natural logarithm, .

Exam-day tip

Read whether the stem gives drawdowns or water heights. Subtract each drawdown from the original saturated thickness before squaring.

Practice more Groundwater

The bank has 10 problems on this subtopic and 100 across Water Resources and Environmental Engineering. Practice quizzes are part of membership. Not a member yet? The free diagnostic shows which areas to work on first. Through December 31, practice quizzes are free with a free account.

More in Water Resources and Environmental Engineering