Skip to content

Free in December. Through December 31, every feature for every exam is free with a free account. No plan, no card.

Free through December 31. Every feature for every exam, free with an account. No plan, no card. Create a free account

Free through December 31. Your account has every feature for every exam until then.

Joining methods

Joining methods is one of the subtopics of Mechanical Design and Analysis in the FE Mechanical exam specification. Questions here are short: one scenario, four choices and about three minutes to answer with the FE Reference Handbook open beside you.

What you can be asked

These are the ideas our problems on Joining methods are built around. Each one is covered by at least one problem in the bank.

  • Bolt preload and tightening torque
  • Bolted joint separation factor of safety
  • Bolt or rivet group in direct shear
  • Eccentric fastener group
  • Bearing and rupture of a riveted plate
  • Fillet weld shear stress

Our practice bank has 6 problems on joining methods. Every problem is a calculation with a numeric answer. 5 of them come with a diagram. 3 use SI units and 3 use US customary units, as the exam mixes both.

Try one: a free Joining methods problem

The solution shows the steps with units, where the equation sits in the Handbook, and the mistake behind each wrong choice.

Free sample US customary units

A 1/2 in diameter steel bolt (d = 0.5 in) clamps the steel flanges of a gearbox housing. The bolt has a tensile-stress area of 0.1419 in², a proof strength of 85 ksi and an ultimate tensile strength of 120 ksi. The assembly specification calls for a preload equal to 75% of the bolt's proof load (proof strength times tensile-stress area). Use a torque coefficient K = 0.2. The tightening torque required (ft·lbf) is most nearly:

  1. A37.7
  2. B75.4
  3. C101
  4. D106

Work it out first. On the exam you would have about three minutes.

Show the answer and worked solution

AnswerB75.4

Find it in the Handbook

Mechanical Engineering

Threaded Fasteners

Approximate tightening torque, , with typically 0.2 for a steel bolt in a steel member (Handbook); the preload of 75% of the proof load is the stem's specification

Search (Ctrl+F)

tightening torquetorque coefficient

Given

  • Steel bolt in steel flanges, in, in²
  • Proof strength ksi; ultimate strength ksi
  • Preload = 75% of the proof load ; torque coefficient

Find

Tightening torque in ft·lbf

  1. Proof load and preload

    Proof load lbf. Preload lbf.

  2. Tightening torque

    in·lbf. Divide by 12 in/ft: ft·lbf.

Why the other choices are wrong

  • A37.7 ft·lbf comes from using the radius, 0.25 in, in place of the diameter: ft·lbf. The torque relation uses the nominal diameter, 0.5 in, which gives 75.4 ft·lbf.
  • C101 ft·lbf comes from using the full proof load, 12062 lbf, as the preload: ft·lbf. The specification asks for 75% of the proof load, lbf, which gives 75.4 ft·lbf.
  • D106 ft·lbf comes from basing the preload on the ultimate strength: lbf, then ft·lbf. Preload is set from the proof strength, 85 ksi, giving lbf and 75.4 ft·lbf.

Exam-day tip

Before you multiply, check which diameter the torque formula wants: it is the nominal bolt diameter, not the radius and not the root or pitch diameter. Then check the torque unit the question asks for, since in lbf and in comes out in in·lbf.