Free sample
Carbon steel bolts are used to fasten fittings of four different metals on marine pump skids, and all are wetted by seawater. Using the Handbook's table of standard oxidation potentials for corrosion reactions, in which assembly do the steel bolts become the anode of a galvanic cell and corrode faster than they would on their own?
- ASteel bolts in zinc fittings
- BSteel bolts in aluminum fittings
- CSteel bolts in magnesium alloy fittings
- DSteel bolts in copper fittings
Work it out first. On the exam you would have about three minutes.
Show the answer and worked solutionHide the answer and worked solution
AnswerDSteel bolts in copper fittings
Find it in the Handbook
Chemistry and Biology
Electrochemistry
Standard oxidation potentials for corrosion reactions (anode half-cells, volts vs. the normal hydrogen electrode); the Materials Science chapter's Corrosion section states that the more electropositive metal becomes the anode
Search (Ctrl+F)
Given
- Carbon steel (iron) bolts in contact with fittings of zinc, aluminum, magnesium or copper
- Seawater as the electrolyte
Find
The pairing in which the steel is the anode
Rule for the anode
Of two dissimilar metals in contact in an electrolyte, the more electropositive one, with the higher oxidation potential in the Handbook's table, becomes the anode and corrodes.
Compare with iron
Iron (Fe → Fe²⁺ + 2e) is +0.440 V. Zinc (+0.763 V), aluminum (+1.662 V) and magnesium (+2.363 V) are higher, so they are anodes and protect the steel. Copper (−0.337 V) is lower, so copper is the cathode and the steel bolts are the anode.
Why the other choices are wrong
- AZinc (+0.763 V) is more electropositive than iron (+0.440 V), so zinc is the anode and corrodes while it protects the steel bolts, which is how galvanizing works. The bolts corrode faster only when the other metal is less electropositive than iron, as copper is.
- BAluminum (+1.662 V) is more electropositive than iron (+0.440 V), so the aluminum fitting is the anode and corrodes; the steel bolts are protected. Steel becomes the anode only against a metal below it in oxidation potential, such as copper (−0.337 V).
- CMagnesium (+2.363 V) is far more electropositive than iron (+0.440 V), so the magnesium alloy fitting corrodes rapidly and the steel bolts are protected. Steel is the anode only against copper (−0.337 V), the one fitting metal with a lower oxidation potential than iron.
Exam-day tip
Find the two metals in the oxidation-potential table and remember that the one with the more positive oxidation potential (lower in the Handbook's table, which runs from negative to positive) is the one that corrodes. Then check the areas: a small anode coupled to a large cathode, like small bolts in a large copper fitting, corrodes fastest.